Testing Anima: one sourced biology figure, start to finish
Anima is an MIT-licensed Claude Code skill that turns a biology mechanism into an interactive, cited figure. We vendored it next to Anatomy, whose drawing kit it shares, and built one new figure with it: caffeine at the A1 adenosine receptor, driven by a human PET study's fit (half the A1 binding at 12.5 mg/L plasma caffeine). Here is the figure, the checks the skill ran, and what those checks cannot catch.
Anima is a Claude Code skill by Natnael Getenew, MIT licensed, built on the drawing kit from Anatomy. You ask for a biology mechanism and it asks you to collect sources first, write one small model, draw the real structures, and then check the result like a reviewer would. Its gallery has six figures, from dopamine receptors to semaglutide.
We already use Anatomy for figures in posts. The two kits share the same core files, so an Anima figure builds and embeds the same way. To test it, we built one new figure from scratch.
The figure
Caffeine keeps you awake mainly by blocking adenosine receptors. On a nerve terminal, adenosine binds the A1 receptor and acts as a brake: the receptor's Gi/o protein releases βγ, which makes the Ca²⁺ channel at the release site harder to open, so glutamate vesicles fuse less often. Caffeine fits the same pocket but does not switch the receptor on.
The only numbers on screen come from one study. Elmenhorst and colleagues gave 15 people caffeine by infusion and measured how much of the A1 PET tracer it pushed off. Half the binding was gone at a plasma level of 12.5 mg/L, and across the study caffeine took between 5% and 44%. The slider stops at 9.5 mg/L (43%), so the figure never shows a share the study did not measure.
What the skill made us do
- Sources before geometry. The figure has five citations. One of them, the PET paper, sets every number. Two claims are flagged by how strong the evidence is: the rise of adenosine with time awake comes from cats, and the switch for it is marked qualitative.
- One pure model.
figures/caffeine-a1/model.mjsholds the fit, and both the readout and the motion read from it. Its eight tests check things a reviewer would ask about. Does 12.5 mg/L give exactly half? Does the paper's rounded 13 mg/L really come to 67 µM for caffeine's molar mass? Does the slider stay inside the measured range? Can caffeine and adenosine ever hold more than every receptor? - The bio audit.
kit/bio-audit.mjschecks that membranes do not cross, that every label points at a part that exists, and that the scale is declared. Our build fails if any of these break, and it also checks that every receptor sits on the terminal's membrane. - Looking at it. We captured it in both themes and at 390 px with the skill's headless-Chrome scripts. At phone width the 960-unit drawing became unreadable, so on a phone it now scrolls sideways inside its card and opens on the receptors.
What the checks cannot catch
A passing audit says the drawing is consistent with itself. It does not say the biology is right. The skill's own reference says so: "A passing geometry check does not validate biological accuracy; review the references separately." We checked the main claims against the papers by hand. The simplifications are listed under the figure: A2A receptors, which matter more for caffeine in the striatum, are left out.
Anima is for teaching. Its drug figures leave out doses on purpose, and so does this one.